diff options
author | Maciej W. Rozycki <macro@linux-mips.org> | 2013-09-12 15:01:53 +0400 |
---|---|---|
committer | Ralf Baechle <ralf@linux-mips.org> | 2013-09-13 13:56:13 +0400 |
commit | daed1285c33582d93447a0ad971bbc1dd15d1940 (patch) | |
tree | ec0f2c412b01cf6944b7f1b448c5a2b8d6827094 /arch/mips/dec/time.c | |
parent | 5a7d8a28080caed7fd4cb1b81d092adac4445e8e (diff) | |
download | linux-daed1285c33582d93447a0ad971bbc1dd15d1940.tar.xz |
MIPS: DECstation HRT initialization rearrangement
Not all I/O ASIC versions have the free-running counter implemented, an
early revision used in the 5000/1xx models aka 3MIN and 4MIN did not have
it. Therefore we cannot unconditionally use it as a clock source.
Fortunately if not implemented its register slot has a fixed value so it
is enough if we check for the value at the end of the calibration period
being the same as at the beginning.
This also means we need to look for another high-precision clock source on
the systems affected. The 5000/1xx can have an R4000SC processor
installed where the CP0 Count register can be used as a clock source.
Unfortunately all the R4k DECstations suffer from the missed timer
interrupt on CP0 Count reads erratum, so we cannot use the CP0 timer as a
clock source and a clock event both at a time. However we never need an
R4k clock event device because all DECstations have a DS1287A RTC chip
whose periodic interrupt can be used as a clock source.
This gives us the following four configuration possibilities for I/O ASIC
DECstations:
1. No I/O ASIC counter and no CP0 timer, e.g. R3k 5000/1xx (3MIN).
2. No I/O ASIC counter but the CP0 timer, i.e. R4k 5000/150 (4MIN).
3. The I/O ASIC counter but no CP0 timer, e.g. R3k 5000/240 (3MAX+).
4. The I/O ASIC counter and the CP0 timer, e.g. R4k 5000/260 (4MAX+).
For #1 and #2 this change stops the I/O ASIC free-running counter from
being installed as a clock source of a 0Hz frequency. For #2 it also
arranges for the CP0 timer to be used as a clock source rather than a
clock event device, because having an accurate wall clock is more
important than a high-precision interval timer. For #3 there is no
change. For #4 the change makes the I/O ASIC free-running counter
installed as a clock source so that the CP0 timer can be used as a clock
event device.
Unfortunately the use of the CP0 timer as a clock event device relies on a
succesful completion of c0_compare_interrupt. That never happens, because
while waiting for a CP0 Compare interrupt to happen the function spins in
a loop reading the CP0 Count register. This makes the CP0 Count erratum
trigger reliably causing the interrupt waited for to be lost in all cases.
As a result #4 resorts to using the CP0 timer as a clock source as well,
just as #2. However we want to keep this separate arrangement in case
(hope) c0_compare_interrupt is eventually rewritten such that it avoids
the erratum.
Signed-off-by: Maciej W. Rozycki <macro@linux-mips.org>
Cc: linux-mips@linux-mips.org
Patchwork: https://patchwork.linux-mips.org/patch/5825/
Signed-off-by: Ralf Baechle <ralf@linux-mips.org>
Diffstat (limited to 'arch/mips/dec/time.c')
-rw-r--r-- | arch/mips/dec/time.c | 22 |
1 files changed, 19 insertions, 3 deletions
diff --git a/arch/mips/dec/time.c b/arch/mips/dec/time.c index 56ebc7f2bede..1914e56f0d96 100644 --- a/arch/mips/dec/time.c +++ b/arch/mips/dec/time.c @@ -125,12 +125,16 @@ int rtc_mips_set_mmss(unsigned long nowtime) void __init plat_time_init(void) { + int ioasic_clock = 0; u32 start, end; int i = HZ / 8; /* Set up the rate of periodic DS1287 interrupts. */ ds1287_set_base_clock(HZ); + /* On some I/O ASIC systems we have the I/O ASIC's counter. */ + if (IOASIC) + ioasic_clock = dec_ioasic_clocksource_init() == 0; if (cpu_has_counter) { ds1287_timer_state(); while (!ds1287_timer_state()) @@ -147,9 +151,21 @@ void __init plat_time_init(void) mips_hpt_frequency = (end - start) * 8; printk(KERN_INFO "MIPS counter frequency %dHz\n", mips_hpt_frequency); - } else if (IOASIC) - /* For pre-R4k systems we use the I/O ASIC's counter. */ - dec_ioasic_clocksource_init(); + + /* + * All R4k DECstations suffer from the CP0 Count erratum, + * so we can't use the timer as a clock source, and a clock + * event both at a time. An accurate wall clock is more + * important than a high-precision interval timer so only + * use the timer as a clock source, and not a clock event + * if there's no I/O ASIC counter available to serve as a + * clock source. + */ + if (!ioasic_clock) { + init_r4k_clocksource(); + mips_hpt_frequency = 0; + } + } ds1287_clockevent_init(dec_interrupt[DEC_IRQ_RTC]); } |