summaryrefslogtreecommitdiff
path: root/arch/arm/boot/dts/sun7i-a20.dtsi
diff options
context:
space:
mode:
authorViresh Kumar <viresh.kumar@linaro.org>2018-11-16 13:01:14 +0300
committerMaxime Ripard <maxime.ripard@bootlin.com>2018-11-19 17:39:32 +0300
commitef4734500407ce4df3985eb55e25c25a98580ac3 (patch)
tree648362f466b4dd3bb3dfba0deafd0bb2e2343f36 /arch/arm/boot/dts/sun7i-a20.dtsi
parenta63ea49a653c5164312aeebf43c50bce5f57ca5a (diff)
downloadlinux-ef4734500407ce4df3985eb55e25c25a98580ac3.tar.xz
ARM: dts: sunxi: Add all CPUs in cooling maps
Each CPU can (and does) participate in cooling down the system but the DT only captures a handful of them, normally CPU0, in the cooling maps. Things work by chance currently as under normal circumstances its the first CPU of each cluster which is used by the operating systems to probe the cooling devices. But as soon as this CPU ordering changes and any other CPU is used to bring up the cooling device, we will start seeing failures. Also the DT is rather incomplete when we list only one CPU in the cooling maps, as the hardware doesn't have any such limitations. Update cooling maps to include all devices affected by individual trip points. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Maxime Ripard <maxime.ripard@bootlin.com>
Diffstat (limited to 'arch/arm/boot/dts/sun7i-a20.dtsi')
-rw-r--r--arch/arm/boot/dts/sun7i-a20.dtsi5
1 files changed, 3 insertions, 2 deletions
diff --git a/arch/arm/boot/dts/sun7i-a20.dtsi b/arch/arm/boot/dts/sun7i-a20.dtsi
index 02e40da9f028..b4fd4f5ca66b 100644
--- a/arch/arm/boot/dts/sun7i-a20.dtsi
+++ b/arch/arm/boot/dts/sun7i-a20.dtsi
@@ -118,7 +118,7 @@
#cooling-cells = <2>;
};
- cpu@1 {
+ cpu1: cpu@1 {
compatible = "arm,cortex-a7";
device_type = "cpu";
reg = <1>;
@@ -148,7 +148,8 @@
cooling-maps {
map0 {
trip = <&cpu_alert0>;
- cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
+ cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
+ <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
};
};