downloadlinux-7eb3f6ffb5c3635e8cc5df7b19741b4bfc5894f5.tar.xz
pwm: Add CLPS711X PWM support
Add a new driver for the ARM CLPS711X Pulse Width Modulator (PWM) interface. This CPU contain two 4-bit PWM outputs with constant period, based on CPU PLL frequency. PWM polarity is determined by hardware by power on reset. Signed-off-by: Alexander Shiyan <shc_work@mail.ru> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/devicetree/bindings/pwm/cirrus,clps711x-pwm.txt16
1 files changed, 16 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/pwm/cirrus,clps711x-pwm.txt b/Documentation/devicetree/bindings/pwm/cirrus,clps711x-pwm.txt
new file mode 100644
index 000000000000..a183db48f910
--- /dev/null
+++ b/Documentation/devicetree/bindings/pwm/cirrus,clps711x-pwm.txt
@@ -0,0 +1,16 @@
+* Cirris Logic CLPS711X PWM controller
+
+Required properties:
+- compatible: Shall contain "cirrus,clps711x-pwm".
+- reg: Physical base address and length of the controller's registers.
+- clocks: phandle + clock specifier pair of the PWM reference clock.
+- #pwm-cells: Should be 1. The cell specifies the index of the channel.
+
+Example:
+ pwm: pwm@80000400 {
+ compatible = "cirrus,ep7312-pwm",
+ "cirrus,clps711x-pwm";
+ reg = <0x80000400 0x4>;
+ clocks = <&clks 8>;
+ #pwm-cells = <1>;
+ };