can: cc770: add platform bus driver for the CC770 and AN82527
This driver works with both, static platform data and device tree bindings. It has been tested on a TQM855L board with two AN82527 CAN controllers on the local bus. CC: Devicetree-discuss@lists.ozlabs.org CC: linuxppc-dev@ozlabs.org CC: Kumar Gala <galak@kernel.crashing.org> Signed-off-by: Wolfgang Grandegger <wg@grandegger.com> Acked-by: Marc Kleine-Budde <mkl@pengutronix.de> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/devicetree/bindings/net/can/cc770.txt53
1 files changed, 53 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/net/can/cc770.txt b/Documentation/devicetree/bindings/net/can/cc770.txt
new file mode 100644
index 000000000000..77027bf6460a
--- /dev/null
+++ b/Documentation/devicetree/bindings/net/can/cc770.txt
@@ -0,0 +1,53 @@
+Memory mapped Bosch CC770 and Intel AN82527 CAN controller
+
+Note: The CC770 is a CAN controller from Bosch, which is 100%
+compatible with the old AN82527 from Intel, but with "bugs" being fixed.
+
+Required properties:
+
+- compatible : should be "bosch,cc770" for the CC770 and "intc,82527"
+ for the AN82527.
+
+- reg : should specify the chip select, address offset and size required
+ to map the registers of the controller. The size is usually 0x80.
+
+- interrupts : property with a value describing the interrupt source
+ (number and sensitivity) required for the controller.
+
+Optional properties:
+
+- bosch,external-clock-frequency : frequency of the external oscillator
+ clock in Hz. Note that the internal clock frequency used by the
+ controller is half of that value. If not specified, a default
+ value of 16000000 (16 MHz) is used.
+
+- bosch,clock-out-frequency : slock frequency in Hz on the CLKOUT pin.
+ If not specified or if the specified value is 0, the CLKOUT pin
+ will be disabled.
+
+- bosch,slew-rate : slew rate of the CLKOUT signal. If not specified,
+ a resonable value will be calculated.
+
+- bosch,disconnect-rx0-input : see data sheet.
+
+- bosch,disconnect-rx1-input : see data sheet.
+
+- bosch,disconnect-tx1-output : see data sheet.
+
+- bosch,polarity-dominant : see data sheet.
+
+- bosch,divide-memory-clock : see data sheet.
+
+- bosch,iso-low-speed-mux : see data sheet.
+
+For further information, please have a look to the CC770 or AN82527.
+
+Examples:
+
+can@3,100 {
+ compatible = "bosch,cc770";
+ reg = <3 0x100 0x80>;
+ interrupts = <2 0>;
+ interrupt-parent = <&mpic>;
+ bosch,external-clock-frequency = <16000000>;
+};