summaryrefslogtreecommitdiff
path: root/Documentation/hwmon/lm25066
diff options
context:
space:
mode:
authorGuenter Roeck <linux@roeck-us.net>2013-02-06 21:55:37 +0400
committerGuenter Roeck <linux@roeck-us.net>2013-04-08 08:16:41 +0400
commita7c69118bdc8647db0e15defa9e399df21a48890 (patch)
treed0838283520993eee5a014b6a54bab8e79169d63 /Documentation/hwmon/lm25066
parent6bf44cedab5918bee8e8fea8c7ad187996c8c874 (diff)
downloadlinux-a7c69118bdc8647db0e15defa9e399df21a48890.tar.xz
hwmon: (pmbus/lm25066) Report VAUX as vmon
So far the driver reported the voltage on VAUX as "vout2". This was not entirely appropriate as it is not an output voltage, and complicates the code. Use the new virtual "VMON" register set and report the voltage as "vmon" instead. Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Diffstat (limited to 'Documentation/hwmon/lm25066')
-rw-r--r--Documentation/hwmon/lm2506616
1 files changed, 8 insertions, 8 deletions
diff --git a/Documentation/hwmon/lm25066 b/Documentation/hwmon/lm25066
index 26025e419d35..2bc5ba6aee66 100644
--- a/Documentation/hwmon/lm25066
+++ b/Documentation/hwmon/lm25066
@@ -60,14 +60,14 @@ in1_max Maximum input voltage.
in1_min_alarm Input voltage low alarm.
in1_max_alarm Input voltage high alarm.
-in2_label "vout1"
-in2_input Measured output voltage.
-in2_average Average measured output voltage.
-in2_min Minimum output voltage.
-in2_min_alarm Output voltage low alarm.
-
-in3_label "vout2"
-in3_input Measured voltage on vaux pin
+in2_label "vmon"
+in2_input Measured voltage on VAUX pin
+
+in3_label "vout1"
+in3_input Measured output voltage.
+in3_average Average measured output voltage.
+in3_min Minimum output voltage.
+in3_min_alarm Output voltage low alarm.
curr1_label "iin"
curr1_input Measured input current.