summaryrefslogtreecommitdiff
path: root/Documentation/hwmon/ibmpowernv
diff options
context:
space:
mode:
authorShilpasri G Bhat <shilpa.bhat@linux.vnet.ibm.com>2018-07-24 12:13:09 +0300
committerMichael Ellerman <mpe@ellerman.id.au>2018-07-31 12:56:45 +0300
commite0da99123f3c80f679d1b40a4321c1478bef14f7 (patch)
tree0be72e061d8a7d6e992248cfbb249333f518a1ad /Documentation/hwmon/ibmpowernv
parent04baaf28f40c68c35a413cd9d0db7139c67e6caf (diff)
downloadlinux-e0da99123f3c80f679d1b40a4321c1478bef14f7.tar.xz
hwmon: (ibmpowernv) Add attributes to enable/disable sensor groups
OPAL firmware provides the facility for some groups of sensors to be enabled/disabled at runtime to give the user the option of using the system resources for collecting these sensors or not. For example, on POWER9 systems, the On Chip Controller (OCC) gathers various system and chip level sensors and maintains their values in main memory. This patch provides support for enabling/disabling the sensor groups like power, temperature, current and voltage. Signed-off-by: Shilpasri G Bhat <shilpa.bhat@linux.vnet.ibm.com> [stewart@linux.vnet.ibm.com: Commit message] Acked-by: Guenter Roeck <linux@roeck-us.net> Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>
Diffstat (limited to 'Documentation/hwmon/ibmpowernv')
-rw-r--r--Documentation/hwmon/ibmpowernv43
1 files changed, 41 insertions, 2 deletions
diff --git a/Documentation/hwmon/ibmpowernv b/Documentation/hwmon/ibmpowernv
index 8826ba29db36..56468258711f 100644
--- a/Documentation/hwmon/ibmpowernv
+++ b/Documentation/hwmon/ibmpowernv
@@ -33,9 +33,48 @@ fanX_input Measured RPM value.
fanX_min Threshold RPM for alert generation.
fanX_fault 0: No fail condition
1: Failing fan
+
tempX_input Measured ambient temperature.
tempX_max Threshold ambient temperature for alert generation.
-inX_input Measured power supply voltage
+tempX_highest Historical maximum temperature
+tempX_lowest Historical minimum temperature
+tempX_enable Enable/disable all temperature sensors belonging to the
+ sub-group. In POWER9, this attribute corresponds to
+ each OCC. Using this attribute each OCC can be asked to
+ disable/enable all of its temperature sensors.
+ 1: Enable
+ 0: Disable
+
+inX_input Measured power supply voltage (millivolt)
inX_fault 0: No fail condition.
1: Failing power supply.
-power1_input System power consumption (microWatt)
+inX_highest Historical maximum voltage
+inX_lowest Historical minimum voltage
+inX_enable Enable/disable all voltage sensors belonging to the
+ sub-group. In POWER9, this attribute corresponds to
+ each OCC. Using this attribute each OCC can be asked to
+ disable/enable all of its voltage sensors.
+ 1: Enable
+ 0: Disable
+
+powerX_input Power consumption (microWatt)
+powerX_input_highest Historical maximum power
+powerX_input_lowest Historical minimum power
+powerX_enable Enable/disable all power sensors belonging to the
+ sub-group. In POWER9, this attribute corresponds to
+ each OCC. Using this attribute each OCC can be asked to
+ disable/enable all of its power sensors.
+ 1: Enable
+ 0: Disable
+
+currX_input Measured current (milliampere)
+currX_highest Historical maximum current
+currX_lowest Historical minimum current
+currX_enable Enable/disable all current sensors belonging to the
+ sub-group. In POWER9, this attribute corresponds to
+ each OCC. Using this attribute each OCC can be asked to
+ disable/enable all of its current sensors.
+ 1: Enable
+ 0: Disable
+
+energyX_input Cumulative energy (microJoule)