summaryrefslogtreecommitdiff
path: root/Documentation/devicetree/bindings/power
diff options
context:
space:
mode:
authorJonathan Bakker <xc-racer2@live.ca>2020-05-15 02:04:35 +0300
committerSebastian Reichel <sre@kernel.org>2020-08-28 20:28:02 +0300
commitd8483f31487c8c8f87fec59c5ee106dd213b177a (patch)
treecceaacc92ec8eaa7b1c24d9a0120f36512f77f84 /Documentation/devicetree/bindings/power
parent683aa86eb16ab8cf91075654d08ef7409f160e35 (diff)
downloadlinux-d8483f31487c8c8f87fec59c5ee106dd213b177a.tar.xz
dt-bindings: power: supply: Cleanup charger-manager bindings
The bindings for charger-manager were very unclear and didn't specify allowable values in many cases. Clean these up to show what each value does and make sure all properties are documented here rather than using wildcards. Signed-off-by: Jonathan Bakker <xc-racer2@live.ca> Acked-by: Rob Herring <robh@kernel.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Diffstat (limited to 'Documentation/devicetree/bindings/power')
-rw-r--r--Documentation/devicetree/bindings/power/supply/charger-manager.txt30
1 files changed, 20 insertions, 10 deletions
diff --git a/Documentation/devicetree/bindings/power/supply/charger-manager.txt b/Documentation/devicetree/bindings/power/supply/charger-manager.txt
index ec4fe9de3137..b5ae9061b7a0 100644
--- a/Documentation/devicetree/bindings/power/supply/charger-manager.txt
+++ b/Documentation/devicetree/bindings/power/supply/charger-manager.txt
@@ -3,24 +3,32 @@ charger-manager bindings
Required properties :
- compatible : "charger-manager"
- - <>-supply : for regulator consumer
- - cm-num-chargers : number of chargers
+ - <>-supply : for regulator consumer, named according to cm-regulator-name
- cm-chargers : name of chargers
- cm-fuel-gauge : name of battery fuel gauge
- subnode <regulator> :
- cm-regulator-name : name of charger regulator
- subnode <cable> :
- - cm-cable-name : name of charger cable
+ - cm-cable-name : name of charger cable - one of USB, USB-HOST,
+ SDP, DCP, CDP, ACA, FAST-CHARGER, SLOW-CHARGER, WPT,
+ PD, DOCK, JIG, or MECHANICAL
- cm-cable-extcon : name of extcon dev
(optional) - cm-cable-min : minimum current of cable
(optional) - cm-cable-max : maximum current of cable
Optional properties :
- cm-name : charger manager's name (default : "battery")
- - cm-poll-mode : polling mode (enum polling_modes)
- - cm-poll-interval : polling interval
- - cm-battery-stat : battery status (enum data_source)
- - cm-fullbatt-* : data for full battery checking
+ - cm-poll-mode : polling mode - 0 for disabled, 1 for always, 2 for when
+ external power is connected, or 3 for when charging. If not present,
+ then polling is disabled
+ - cm-poll-interval : polling interval (in ms)
+ - cm-battery-stat : battery status - 0 for battery always present, 1 for no
+ battery, 2 to check presence via fuel gauge, or 3 to check presence
+ via charger
+ - cm-fullbatt-vchkdrop-volt : voltage drop (in uV) before restarting charging
+ - cm-fullbatt-voltage : voltage (in uV) of full battery
+ - cm-fullbatt-soc : state of charge to consider as full battery
+ - cm-fullbatt-capacity : capcity (in uAh) to consider as full battery
- cm-thermal-zone : name of external thermometer's thermal zone
- cm-battery-* : threshold battery temperature for charging
-cold : critical cold temperature of battery for charging
@@ -29,6 +37,10 @@ Optional properties :
-temp-diff : temperature difference to allow recharging
- cm-dis/charging-max = limits of charging duration
+Deprecated properties:
+ - cm-num-chargers
+ - cm-fullbatt-vchkdrop-ms
+
Example :
charger-manager@0 {
compatible = "charger-manager";
@@ -39,13 +51,11 @@ Example :
cm-poll-mode = <1>;
cm-poll-interval = <30000>;
- cm-fullbatt-vchkdrop-ms = <30000>;
cm-fullbatt-vchkdrop-volt = <150000>;
cm-fullbatt-soc = <100>;
cm-battery-stat = <3>;
- cm-num-chargers = <3>;
cm-chargers = "charger0", "charger1", "charger2";
cm-fuel-gauge = "fuelgauge0";
@@ -71,7 +81,7 @@ Example :
cm-cable-max = <500000>;
};
cable@1 {
- cm-cable-name = "TA";
+ cm-cable-name = "SDP";
cm-cable-extcon = "extcon-dev.0";
cm-cable-min = <650000>;
cm-cable-max = <675000>;