iio: chemical: bme680: Fix pressure value output
The IIO standard units are measured in kPa while the driver is using hPa. Apart from checking the userspace value itself, it is mentioned also in the Bosch API [1] that the pressure value is in Pascal. [1]: https://github.com/boschsensortec/BME68x_SensorAPI/blob/v4.4.8/bme68x_defs.h#L742 Fixes: 1b3bd8592780 ("iio: chemical: Add support for Bosch BME680 sensor") Signed-off-by: Vasileios Amoiridis <vassilisamir@gmail.com> Link: https://lore.kernel.org/r/20240606212313.207550-2-vassilisamir@gmail.com Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
-rw-r--r--drivers/iio/chemical/bme680_core.c2
1 files changed, 1 insertions, 1 deletions
diff --git a/drivers/iio/chemical/bme680_core.c b/drivers/iio/chemical/bme680_core.c
index ef5e0e46fd34..2c40c13fe97a 100644
--- a/drivers/iio/chemical/bme680_core.c
+++ b/drivers/iio/chemical/bme680_core.c
@@ -678,7 +678,7 @@ static int bme680_read_press(struct bme680_data *data,
}
*val = bme680_compensate_press(data, adc_press);
- *val2 = 100;
+ *val2 = 1000;