meta-facebook: yosemite4: Power fault event
Summary:
The system shall register an event in the case of BIC and CPU power fault.
BMC is triggered by INT_SMB_BMC_SLOT1_4_N or INT_SMB_BMC_SLOT5_8_N, checking
which SLOT got power fault via reading the MUX (i2c-bus 8, 0x70 for SLOT1-4,
and i2c-bus 9, 0x71 for SLOT1-4).
Then, BMC reads CPLD IOE for each failed SLOT to check affected power rails.
For BIC power fault, check address 0x24, port 1:
bit
[1] PWRGD_P1V2_STBY_FAULT
[0] PWRGD_P1V8_STBY_FAULT
For CPU power fault, check address 0x24, port 2:
bit
[4] PWRGD_PVDD11_S3_R_FAULT
[3] PWRGD_PVDDIO_FAULT
[2] PWRGD_PVDDCR_CPU1_FAULT
[1] PWRGD_PVDDCR_SOC_FAULT
[0] PWRGD_PVDDCR_CPU0_FAULT
Test Plan:
Trigger power fault by setting CPLD (0x0F) on server board
to pull INT_SMB_BMC_SLOT1_4_N or INT_SMB_BMC_SLOT5_8_N low.
Testing:
Take SLOT2 for example.
1. Check gpio status
root@bmc:~# cat /sys/kernel/debug/gpio | grep -i 1_4
gpio-612 (INT_SMB_BMC_SLOT1_4_|gpio_monitor ) in hi IRQ
2. Check (1 to 4)MUX status
root@bmc:~# i2ctransfer -f -y 8 w1@0x70 0 r1
0x00
3. Check SLOT2 CPLD IOE status
root@bmc:~# i2ctransfer -y -f 1 w1@0x24 0x01 r1
0x00
root@bmc:~# i2ctransfer -y -f 1 w1@0x24 0x02 r1
0x00
4. Trigger power fault by setting CPLD (0x0F) on server board
root@bmc:~# i2ctransfer -y -f 1 w2@0xf 0x3f 0x1
5. Check event log
root@bmc:~# mfg-tool log-display
...
},
"2": {
"additional_data": [
"FAULT=PWRGD_P1V8_STBY_FAULT"
],
"event_id": "",
"message": "SLOT2 AC Power Fault",
"resolution": "",
"resolved": false,
"severity": "xyz.openbmc_project.Logging.Entry.Level.Error",
"timestamp": "2024-07-18T08:37:13.179000000Z",
"updated_timestamp": "2024-07-18T08:37:13.179000000Z"
},
"3": {
"additional_data": [
"FAULT=PWRGD_PVDDCR_CPU0_FAULT"
],
"event_id": "",
"message": "SLOT2 DC Power Fault",
"resolution": "",
"resolved": false,
"severity": "xyz.openbmc_project.Logging.Entry.Level.Error",
"timestamp": "2024-07-18T08:37:13.231000000Z",
"updated_timestamp": "2024-07-18T08:37:13.231000000Z"
}
6. Check gpio status
root@bmc:~# cat /sys/kernel/debug/gpio | grep -i 1_4
gpio-612 (INT_SMB_BMC_SLOT1_4_|gpio_monitor ) in lo IRQ
7. Check (1 to 4)MUX status
root@bmc:~# i2ctransfer -f -y 8 w1@0x70 0 r1
0x20
8. Check SLOT2 CPLD IOE status
root@bmc:~# i2ctransfer -y -f 1 w1@0x24 0x01 r1
0x01
root@bmc:~# i2ctransfer -y -f 1 w1@0x24 0x02 r1
0x01
Change-Id: I67b93e9a55c949af54aee4ca90dc998448bdfdcc
Signed-off-by: Yikai Tsai <yikai.tsai.wiwynn@gmail.com>