From 655f376a240ce73f7c3fb6f37cd6da0cbce1693e Mon Sep 17 00:00:00 2001
From: James Feist <james.feist@linux.intel.com>
Date: Mon, 5 Oct 2020 15:28:15 -0700
Subject: [PATCH 1/1] ExitAir: Move to GetSensorConfiguration
GetSensorConfiguration has improved to have retries
and avoid more expensive GetManagedOjects calls. Use
it.
Tested: System Airflow still worked
Change-Id: Icbbabb6ebda771b9cde563559a83f633ffc3769f
Signed-off-by: James Feist <james.feist@linux.intel.com>
---
src/ExitAirTempSensor.cpp | 23 ++++++++++-------------
1 file changed, 10 insertions(+), 13 deletions(-)
diff --git a/src/ExitAirTempSensor.cpp b/src/ExitAirTempSensor.cpp
index 41d9a19..c667457 100644
--- a/src/ExitAirTempSensor.cpp
+++ b/src/ExitAirTempSensor.cpp
@@ -61,6 +61,9 @@ static constexpr double cfmMinReading = 0;
static constexpr size_t minSystemCfm = 50;
+constexpr const std::array<const char*, 2> monitorIfaces = {exitAirIface,
+ cfmIface};
+
static std::vector<std::shared_ptr<CFMSensor>> cfmSensors;
static void setupSensorMatch(
@@ -827,14 +830,10 @@ void createSensor(sdbusplus::asio::object_server& objectServer,
std::cerr << "Connection not created\n";
return;
}
- dbusConnection->async_method_call(
- [&](boost::system::error_code ec, const ManagedObjectType& resp) {
- if (ec)
- {
- std::cerr << "Error contacting entity manager\n";
- return;
- }
-
+ auto getter = std::make_shared<GetSensorConfiguration>(
+ dbusConnection,
+ std::move([&objectServer, &dbusConnection,
+ &exitAirSensor](const ManagedObjectType& resp) {
cfmSensors.clear();
for (const auto& pathPair : resp)
{
@@ -908,9 +907,9 @@ void createSensor(sdbusplus::asio::object_server& objectServer,
exitAirSensor->setupMatches();
exitAirSensor->updateReading();
}
- },
- entityManagerName, "/", "org.freedesktop.DBus.ObjectManager",
- "GetManagedObjects");
+ }));
+ getter->getConfiguration(
+ std::vector<std::string>(monitorIfaces.begin(), monitorIfaces.end()));
}
int main()
@@ -944,8 +943,6 @@ int main()
}
});
};
- constexpr const std::array<const char*, 2> monitorIfaces = {exitAirIface,
- cfmIface};
for (const char* type : monitorIfaces)
{
auto match = std::make_unique<sdbusplus::bus::match::match>(
--
2.17.1
|