From 3594f4c0d7bc51e3a7e6d73c44e368ae079e42f3 Mon Sep 17 00:00:00 2001 From: Kees Cook Date: Thu, 6 Jun 2013 13:52:21 -0700 Subject: charger-manager: Ensure event is not used as format string The exposed interface for cm_notify_event() could result in the event msg string being parsed as a format string. Make sure it is only used as a literal string. Signed-off-by: Kees Cook Cc: stable@vger.kernel.org Cc: Anton Vorontsov Cc: David Woodhouse Signed-off-by: Anton Vorontsov --- drivers/power/charger-manager.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) (limited to 'drivers/power/charger-manager.c') diff --git a/drivers/power/charger-manager.c b/drivers/power/charger-manager.c index fefc39fe42be..98de1ddce458 100644 --- a/drivers/power/charger-manager.c +++ b/drivers/power/charger-manager.c @@ -450,7 +450,7 @@ static void uevent_notify(struct charger_manager *cm, const char *event) strncpy(env_str, event, UEVENT_BUF_SIZE); kobject_uevent(&cm->dev->kobj, KOBJ_CHANGE); - dev_info(cm->dev, event); + dev_info(cm->dev, "%s", event); } /** -- cgit v1.2.3 From e5409cbd8c0bf44f65e7528635cf05ed298e0c61 Mon Sep 17 00:00:00 2001 From: Joe Perches Date: Thu, 6 Jun 2013 18:25:12 -0700 Subject: charger-manager: Add missing newlines, fix a couple of typos, add pr_fmt Make sure that dev_ calls are newline terminated. Add #define pr_fmt(fmt) KBUILD_MODNAME ": " fmt to prefix all pr_ calls with "charger-manager: " Fix a couple of typos. Fix formats with terminating n that should be \n. Coalesce formats for easier grep. Align arguments to open parenthesis for these dev_ calls. Add missing spaces after coalescing multiple string segments. Signed-off-by: Joe Perches Acked-by: Kees Cook Signed-off-by: Anton Vorontsov --- drivers/power/charger-manager.c | 137 +++++++++++++++++----------------------- 1 file changed, 57 insertions(+), 80 deletions(-) (limited to 'drivers/power/charger-manager.c') diff --git a/drivers/power/charger-manager.c b/drivers/power/charger-manager.c index 98de1ddce458..ba420292628e 100644 --- a/drivers/power/charger-manager.c +++ b/drivers/power/charger-manager.c @@ -12,6 +12,8 @@ * published by the Free Software Foundation. **/ +#define pr_fmt(fmt) KBUILD_MODNAME ": " fmt + #include #include #include @@ -195,8 +197,8 @@ static bool is_charging(struct charger_manager *cm) cm->charger_stat[i], POWER_SUPPLY_PROP_ONLINE, &val); if (ret) { - dev_warn(cm->dev, "Cannot read ONLINE value from %s.\n", - cm->desc->psy_charger_stat[i]); + dev_warn(cm->dev, "Cannot read ONLINE value from %s\n", + cm->desc->psy_charger_stat[i]); continue; } if (val.intval == 0) @@ -210,8 +212,8 @@ static bool is_charging(struct charger_manager *cm) cm->charger_stat[i], POWER_SUPPLY_PROP_STATUS, &val); if (ret) { - dev_warn(cm->dev, "Cannot read STATUS value from %s.\n", - cm->desc->psy_charger_stat[i]); + dev_warn(cm->dev, "Cannot read STATUS value from %s\n", + cm->desc->psy_charger_stat[i]); continue; } if (val.intval == POWER_SUPPLY_STATUS_FULL || @@ -289,7 +291,7 @@ static bool is_polling_required(struct charger_manager *cm) return is_charging(cm); default: dev_warn(cm->dev, "Incorrect polling_mode (%d)\n", - cm->desc->polling_mode); + cm->desc->polling_mode); } return false; @@ -331,9 +333,8 @@ static int try_charger_enable(struct charger_manager *cm, bool enable) err = regulator_enable(desc->charger_regulators[i].consumer); if (err < 0) { - dev_warn(cm->dev, - "Cannot enable %s regulator\n", - desc->charger_regulators[i].regulator_name); + dev_warn(cm->dev, "Cannot enable %s regulator\n", + desc->charger_regulators[i].regulator_name); } } } else { @@ -350,9 +351,8 @@ static int try_charger_enable(struct charger_manager *cm, bool enable) err = regulator_disable(desc->charger_regulators[i].consumer); if (err < 0) { - dev_warn(cm->dev, - "Cannot disable %s regulator\n", - desc->charger_regulators[i].regulator_name); + dev_warn(cm->dev, "Cannot disable %s regulator\n", + desc->charger_regulators[i].regulator_name); } } @@ -365,9 +365,8 @@ static int try_charger_enable(struct charger_manager *cm, bool enable) desc->charger_regulators[i].consumer)) { regulator_force_disable( desc->charger_regulators[i].consumer); - dev_warn(cm->dev, - "Disable regulator(%s) forcibly.\n", - desc->charger_regulators[i].regulator_name); + dev_warn(cm->dev, "Disable regulator(%s) forcibly\n", + desc->charger_regulators[i].regulator_name); } } } @@ -450,7 +449,7 @@ static void uevent_notify(struct charger_manager *cm, const char *event) strncpy(env_str, event, UEVENT_BUF_SIZE); kobject_uevent(&cm->dev->kobj, KOBJ_CHANGE); - dev_info(cm->dev, "%s", event); + dev_info(cm->dev, "%s\n", event); } /** @@ -478,7 +477,7 @@ static void fullbatt_vchk(struct work_struct *work) err = get_batt_uV(cm, &batt_uV); if (err) { - dev_err(cm->dev, "%s: get_batt_uV error(%d).\n", __func__, err); + dev_err(cm->dev, "%s: get_batt_uV error(%d)\n", __func__, err); return; } @@ -486,7 +485,7 @@ static void fullbatt_vchk(struct work_struct *work) if (diff < 0) return; - dev_info(cm->dev, "VBATT dropped %duV after full-batt.\n", diff); + dev_info(cm->dev, "VBATT dropped %duV after full-batt\n", diff); if (diff > desc->fullbatt_vchkdrop_uV) { try_charger_restart(cm); @@ -519,7 +518,7 @@ static int check_charging_duration(struct charger_manager *cm) duration = curr - cm->charging_start_time; if (duration > desc->charging_max_duration_ms) { - dev_info(cm->dev, "Charging duration exceed %lldms", + dev_info(cm->dev, "Charging duration exceed %lldms\n", desc->charging_max_duration_ms); uevent_notify(cm, "Discharging"); try_charger_enable(cm, false); @@ -530,9 +529,9 @@ static int check_charging_duration(struct charger_manager *cm) if (duration > desc->charging_max_duration_ms && is_ext_pwr_online(cm)) { - dev_info(cm->dev, "DisCharging duration exceed %lldms", + dev_info(cm->dev, "Discharging duration exceed %lldms\n", desc->discharging_max_duration_ms); - uevent_notify(cm, "Recharing"); + uevent_notify(cm, "Recharging"); try_charger_enable(cm, true); ret = true; } @@ -579,7 +578,7 @@ static bool _cm_monitor(struct charger_manager *cm) */ } else if (!cm->emergency_stop && check_charging_duration(cm)) { dev_dbg(cm->dev, - "Charging/Discharging duration is out of range"); + "Charging/Discharging duration is out of range\n"); /* * Check dropped voltage of battery. If battery voltage is more * dropped than fullbatt_vchkdrop_uV after fully charged state, @@ -595,7 +594,7 @@ static bool _cm_monitor(struct charger_manager *cm) */ } else if (!cm->emergency_stop && is_full_charged(cm) && cm->charger_enabled) { - dev_info(cm->dev, "EVENT_HANDLE: Battery Fully Charged.\n"); + dev_info(cm->dev, "EVENT_HANDLE: Battery Fully Charged\n"); uevent_notify(cm, default_event_names[CM_EVENT_BATT_FULL]); try_charger_enable(cm, false); @@ -725,7 +724,7 @@ static void fullbatt_handler(struct charger_manager *cm) cm->fullbatt_vchk_jiffies_at = 1; out: - dev_info(cm->dev, "EVENT_HANDLE: Battery Fully Charged.\n"); + dev_info(cm->dev, "EVENT_HANDLE: Battery Fully Charged\n"); uevent_notify(cm, default_event_names[CM_EVENT_BATT_FULL]); } @@ -972,7 +971,7 @@ static bool cm_setup_timer(void) mutex_unlock(&cm_list_mtx); if (wakeup_ms < UINT_MAX && wakeup_ms > 0) { - pr_info("Charger Manager wakeup timer: %u ms.\n", wakeup_ms); + pr_info("Charger Manager wakeup timer: %u ms\n", wakeup_ms); if (rtc_dev) { struct rtc_wkalrm tmp; unsigned long time, now; @@ -1005,8 +1004,7 @@ static bool cm_setup_timer(void) ret = false; } - pr_info("Waking up after %lu secs.\n", - time - now); + pr_info("Waking up after %lu secs\n", time - now); rtc_time_to_tm(time, &tmp.time); rtc_set_alarm(rtc_dev, &tmp); @@ -1101,7 +1099,7 @@ int setup_charger_manager(struct charger_global_desc *gd) g_desc = NULL; if (!gd->rtc_only_wakeup) { - pr_err("The callback rtc_only_wakeup is not given.\n"); + pr_err("The callback rtc_only_wakeup is not given\n"); return -EINVAL; } @@ -1112,7 +1110,7 @@ int setup_charger_manager(struct charger_global_desc *gd) /* Retry at probe. RTC may be not registered yet */ } } else { - pr_warn("No wakeup timer is given for charger manager." + pr_warn("No wakeup timer is given for charger manager. " "In-suspend monitoring won't work.\n"); } @@ -1138,13 +1136,13 @@ static void charger_extcon_work(struct work_struct *work) cable->min_uA, cable->max_uA); if (ret < 0) { pr_err("Cannot set current limit of %s (%s)\n", - cable->charger->regulator_name, cable->name); + cable->charger->regulator_name, cable->name); return; } pr_info("Set current limit of %s : %duA ~ %duA\n", - cable->charger->regulator_name, - cable->min_uA, cable->max_uA); + cable->charger->regulator_name, + cable->min_uA, cable->max_uA); } try_charger_enable(cable->cm, cable->attached); @@ -1210,9 +1208,8 @@ static int charger_extcon_init(struct charger_manager *cm, ret = extcon_register_interest(&cable->extcon_dev, cable->extcon_name, cable->name, &cable->nb); if (ret < 0) { - pr_info("Cannot register extcon_dev for %s(cable: %s).\n", - cable->extcon_name, - cable->name); + pr_info("Cannot register extcon_dev for %s(cable: %s)\n", + cable->extcon_name, cable->name); ret = -EINVAL; } @@ -1243,8 +1240,8 @@ static int charger_manager_register_extcon(struct charger_manager *cm) charger->consumer = regulator_get(cm->dev, charger->regulator_name); if (charger->consumer == NULL) { - dev_err(cm->dev, "Cannot find charger(%s)n", - charger->regulator_name); + dev_err(cm->dev, "Cannot find charger(%s)\n", + charger->regulator_name); ret = -EINVAL; goto err; } @@ -1255,8 +1252,8 @@ static int charger_manager_register_extcon(struct charger_manager *cm) ret = charger_extcon_init(cm, cable); if (ret < 0) { - dev_err(cm->dev, "Cannot initialize charger(%s)n", - charger->regulator_name); + dev_err(cm->dev, "Cannot initialize charger(%s)\n", + charger->regulator_name); goto err; } cable->charger = charger; @@ -1347,10 +1344,8 @@ static ssize_t charger_externally_control_store(struct device *dev, } } else { dev_warn(cm->dev, - "'%s' regulator should be controlled " - "in charger-manager because charger-manager " - "must need at least one charger for charging\n", - charger->regulator_name); + "'%s' regulator should be controlled in charger-manager because charger-manager must need at least one charger for charging\n", + charger->regulator_name); } return count; @@ -1386,8 +1381,6 @@ static int charger_manager_register_sysfs(struct charger_manager *cm) snprintf(buf, 10, "charger.%d", i); str = kzalloc(sizeof(char) * (strlen(buf) + 1), GFP_KERNEL); if (!str) { - dev_err(cm->dev, "Cannot allocate memory: %s\n", - charger->regulator_name); ret = -ENOMEM; goto err; } @@ -1423,26 +1416,21 @@ static int charger_manager_register_sysfs(struct charger_manager *cm) !chargers_externally_control) chargers_externally_control = 0; - dev_info(cm->dev, "'%s' regulator's externally_control" - "is %d\n", charger->regulator_name, - charger->externally_control); + dev_info(cm->dev, "'%s' regulator's externally_control is %d\n", + charger->regulator_name, charger->externally_control); ret = sysfs_create_group(&cm->charger_psy.dev->kobj, &charger->attr_g); if (ret < 0) { - dev_err(cm->dev, "Cannot create sysfs entry" - "of %s regulator\n", - charger->regulator_name); + dev_err(cm->dev, "Cannot create sysfs entry of %s regulator\n", + charger->regulator_name); ret = -EINVAL; goto err; } } if (chargers_externally_control) { - dev_err(cm->dev, "Cannot register regulator because " - "charger-manager must need at least " - "one charger for charging battery\n"); - + dev_err(cm->dev, "Cannot register regulator because charger-manager must need at least one charger for charging battery\n"); ret = -EINVAL; goto err; } @@ -1463,7 +1451,7 @@ static int charger_manager_probe(struct platform_device *pdev) rtc_dev = rtc_class_open(g_desc->rtc_name); if (IS_ERR_OR_NULL(rtc_dev)) { rtc_dev = NULL; - dev_err(&pdev->dev, "Cannot get RTC %s.\n", + dev_err(&pdev->dev, "Cannot get RTC %s\n", g_desc->rtc_name); ret = -ENODEV; goto err_alloc; @@ -1471,14 +1459,13 @@ static int charger_manager_probe(struct platform_device *pdev) } if (!desc) { - dev_err(&pdev->dev, "No platform data (desc) found.\n"); + dev_err(&pdev->dev, "No platform data (desc) found\n"); ret = -ENODEV; goto err_alloc; } cm = kzalloc(sizeof(struct charger_manager), GFP_KERNEL); if (!cm) { - dev_err(&pdev->dev, "Cannot allocate memory.\n"); ret = -ENOMEM; goto err_alloc; } @@ -1487,7 +1474,6 @@ static int charger_manager_probe(struct platform_device *pdev) cm->dev = &pdev->dev; cm->desc = kmemdup(desc, sizeof(struct charger_desc), GFP_KERNEL); if (!cm->desc) { - dev_err(&pdev->dev, "Cannot allocate memory.\n"); ret = -ENOMEM; goto err_alloc_desc; } @@ -1498,33 +1484,28 @@ static int charger_manager_probe(struct platform_device *pdev) * Users may intentionally ignore those two features. */ if (desc->fullbatt_uV == 0) { - dev_info(&pdev->dev, "Ignoring full-battery voltage threshold" - " as it is not supplied."); + dev_info(&pdev->dev, "Ignoring full-battery voltage threshold as it is not supplied\n"); } if (!desc->fullbatt_vchkdrop_ms || !desc->fullbatt_vchkdrop_uV) { - dev_info(&pdev->dev, "Disabling full-battery voltage drop " - "checking mechanism as it is not supplied."); + dev_info(&pdev->dev, "Disabling full-battery voltage drop checking mechanism as it is not supplied\n"); desc->fullbatt_vchkdrop_ms = 0; desc->fullbatt_vchkdrop_uV = 0; } if (desc->fullbatt_soc == 0) { - dev_info(&pdev->dev, "Ignoring full-battery soc(state of" - " charge) threshold as it is not" - " supplied."); + dev_info(&pdev->dev, "Ignoring full-battery soc(state of charge) threshold as it is not supplied\n"); } if (desc->fullbatt_full_capacity == 0) { - dev_info(&pdev->dev, "Ignoring full-battery full capacity" - " threshold as it is not supplied."); + dev_info(&pdev->dev, "Ignoring full-battery full capacity threshold as it is not supplied\n"); } if (!desc->charger_regulators || desc->num_charger_regulators < 1) { ret = -EINVAL; - dev_err(&pdev->dev, "charger_regulators undefined.\n"); + dev_err(&pdev->dev, "charger_regulators undefined\n"); goto err_no_charger; } if (!desc->psy_charger_stat || !desc->psy_charger_stat[0]) { - dev_err(&pdev->dev, "No power supply defined.\n"); + dev_err(&pdev->dev, "No power supply defined\n"); ret = -EINVAL; goto err_no_charger_stat; } @@ -1544,9 +1525,8 @@ static int charger_manager_probe(struct platform_device *pdev) cm->charger_stat[i] = power_supply_get_by_name( desc->psy_charger_stat[i]); if (!cm->charger_stat[i]) { - dev_err(&pdev->dev, "Cannot find power supply " - "\"%s\"\n", - desc->psy_charger_stat[i]); + dev_err(&pdev->dev, "Cannot find power supply \"%s\"\n", + desc->psy_charger_stat[i]); ret = -ENODEV; goto err_chg_stat; } @@ -1555,7 +1535,7 @@ static int charger_manager_probe(struct platform_device *pdev) cm->fuel_gauge = power_supply_get_by_name(desc->psy_fuel_gauge); if (!cm->fuel_gauge) { dev_err(&pdev->dev, "Cannot find power supply \"%s\"\n", - desc->psy_fuel_gauge); + desc->psy_fuel_gauge); ret = -ENODEV; goto err_chg_stat; } @@ -1575,9 +1555,7 @@ static int charger_manager_probe(struct platform_device *pdev) if (!desc->charging_max_duration_ms || !desc->discharging_max_duration_ms) { - dev_info(&pdev->dev, "Cannot limit charging duration " - "checking mechanism to prevent overcharge/overheat " - "and control discharging duration"); + dev_info(&pdev->dev, "Cannot limit charging duration checking mechanism to prevent overcharge/overheat and control discharging duration\n"); desc->charging_max_duration_ms = 0; desc->discharging_max_duration_ms = 0; } @@ -1598,7 +1576,6 @@ static int charger_manager_probe(struct platform_device *pdev) NUM_CHARGER_PSY_OPTIONAL), GFP_KERNEL); if (!cm->charger_psy.properties) { - dev_err(&pdev->dev, "Cannot allocate for psy properties.\n"); ret = -ENOMEM; goto err_chg_stat; } @@ -1636,8 +1613,8 @@ static int charger_manager_probe(struct platform_device *pdev) ret = power_supply_register(NULL, &cm->charger_psy); if (ret) { - dev_err(&pdev->dev, "Cannot register charger-manager with" - " name \"%s\".\n", cm->charger_psy.name); + dev_err(&pdev->dev, "Cannot register charger-manager with name \"%s\"\n", + cm->charger_psy.name); goto err_register; } @@ -1948,7 +1925,7 @@ void cm_notify_event(struct power_supply *psy, enum cm_event_types type, uevent_notify(cm, msg ? msg : default_event_names[type]); break; default: - dev_err(cm->dev, "%s type not specified.\n", __func__); + dev_err(cm->dev, "%s: type not specified\n", __func__); break; } } -- cgit v1.2.3 From 3cc9d26966ea02f71258ab0553ebd3388f40533a Mon Sep 17 00:00:00 2001 From: Jonghwa Lee Date: Tue, 25 Jun 2013 14:02:49 +0900 Subject: charger-manager: Fix a bug when it unregisters notifier block of extcon This patch prevents NULL pointer error cauesed by unregistering unregistered exton notifier block. At the probing time of charger manager, it tries to remove extcon notifier block when it fails to initialize them. It has to be applied for only registered one. Otherwise, it'd make kernel panic. To make it work right, it checks extcon_specific_cable_nb's extcon_dev node. If extcon cable notifier block was registered successfully, it has proper extcon_dev pointer if not so it has NULL pointer. Signed-off-by: Jonghwa Lee Signed-off-by: Myungjoo Ham Acked-by: Chanwoo Choi Signed-off-by: Anton Vorontsov --- drivers/power/charger-manager.c | 4 +++- 1 file changed, 3 insertions(+), 1 deletion(-) (limited to 'drivers/power/charger-manager.c') diff --git a/drivers/power/charger-manager.c b/drivers/power/charger-manager.c index ba420292628e..8ad9698b55a9 100644 --- a/drivers/power/charger-manager.c +++ b/drivers/power/charger-manager.c @@ -1666,7 +1666,9 @@ err_reg_extcon: charger = &desc->charger_regulators[i]; for (j = 0; j < charger->num_cables; j++) { struct charger_cable *cable = &charger->cables[j]; - extcon_unregister_interest(&cable->extcon_dev); + /* Remove notifier block if only edev exists */ + if (cable->extcon_dev.edev) + extcon_unregister_interest(&cable->extcon_dev); } regulator_put(desc->charger_regulators[i].consumer); -- cgit v1.2.3 From 5a6c2208455f25b3e6f939adc2da59aa00d4806e Mon Sep 17 00:00:00 2001 From: Jonghwa Lee Date: Tue, 25 Jun 2013 14:18:14 +0900 Subject: charger-manager: Fix regulator_get() return check This patch fixes return value checking of regulator_get() in charger-manager driver. The API, regulator_get(), returns ERR_PTR() when it fails to get regulator with given name, not NULL. Signed-off-by: Jonghwa Lee Signed-off-by: Myungjoo Ham Acked-by: Chanwoo Choi Signed-off-by: Anton Vorontsov --- drivers/power/charger-manager.c | 5 ++--- 1 file changed, 2 insertions(+), 3 deletions(-) (limited to 'drivers/power/charger-manager.c') diff --git a/drivers/power/charger-manager.c b/drivers/power/charger-manager.c index 8ad9698b55a9..e30e847600bb 100644 --- a/drivers/power/charger-manager.c +++ b/drivers/power/charger-manager.c @@ -1239,11 +1239,10 @@ static int charger_manager_register_extcon(struct charger_manager *cm) charger->consumer = regulator_get(cm->dev, charger->regulator_name); - if (charger->consumer == NULL) { + if (IS_ERR(charger->consumer)) { dev_err(cm->dev, "Cannot find charger(%s)\n", charger->regulator_name); - ret = -EINVAL; - goto err; + return PTR_ERR(charger->consumer); } charger->cm = cm; -- cgit v1.2.3