From f5f263fed66f75a4482d7ad49392b4283a05885a Mon Sep 17 00:00:00 2001 From: Viresh Kumar Date: Tue, 5 Dec 2017 11:02:43 +0530 Subject: cpu_cooling: Make of_cpufreq_power_cooling_register() parse DT All the callers of of_cpufreq_power_cooling_register() have almost identical code and it makes more sense to move that code into the helper as its all about reading DT properties. This got rid of lot of redundant code. Acked-by: Eduardo Valentin Signed-off-by: Viresh Kumar Signed-off-by: Rafael J. Wysocki --- drivers/cpufreq/mediatek-cpufreq.c | 22 +--------------------- 1 file changed, 1 insertion(+), 21 deletions(-) (limited to 'drivers/cpufreq/mediatek-cpufreq.c') diff --git a/drivers/cpufreq/mediatek-cpufreq.c b/drivers/cpufreq/mediatek-cpufreq.c index e0d5090b303d..6ff783e1b18a 100644 --- a/drivers/cpufreq/mediatek-cpufreq.c +++ b/drivers/cpufreq/mediatek-cpufreq.c @@ -310,28 +310,8 @@ static int mtk_cpufreq_set_target(struct cpufreq_policy *policy, static void mtk_cpufreq_ready(struct cpufreq_policy *policy) { struct mtk_cpu_dvfs_info *info = policy->driver_data; - struct device_node *np = of_node_get(info->cpu_dev->of_node); - u32 capacitance = 0; - if (WARN_ON(!np)) - return; - - if (of_find_property(np, "#cooling-cells", NULL)) { - of_property_read_u32(np, DYNAMIC_POWER, &capacitance); - - info->cdev = of_cpufreq_power_cooling_register(np, - policy, capacitance, NULL); - - if (IS_ERR(info->cdev)) { - dev_err(info->cpu_dev, - "running cpufreq without cooling device: %ld\n", - PTR_ERR(info->cdev)); - - info->cdev = NULL; - } - } - - of_node_put(np); + info->cdev = of_cpufreq_power_cooling_register(policy); } static int mtk_cpu_dvfs_info_init(struct mtk_cpu_dvfs_info *info, int cpu) -- cgit v1.2.3 From 3ebb62ffc4e4817c3288cdf7ed67ccaf453385e3 Mon Sep 17 00:00:00 2001 From: Viresh Kumar Date: Tue, 5 Dec 2017 11:02:45 +0530 Subject: cpu_cooling: Keep only one of_cpufreq*cooling_register() helper of_cpufreq_cooling_register() isn't used by anyone and so can be removed, but then we would be left with two routines: cpufreq_cooling_register() and of_cpufreq_power_cooling_register() that would look odd. Remove current implementation of of_cpufreq_cooling_register() and rename of_cpufreq_power_cooling_register() as of_cpufreq_cooling_register(). This simplifies lots of stuff. Acked-by: Eduardo Valentin Signed-off-by: Viresh Kumar Signed-off-by: Rafael J. Wysocki --- Documentation/thermal/cpu-cooling-api.txt | 14 ++------ drivers/cpufreq/arm_big_little.c | 2 +- drivers/cpufreq/cpufreq-dt.c | 2 +- drivers/cpufreq/mediatek-cpufreq.c | 2 +- drivers/cpufreq/qoriq-cpufreq.c | 2 +- drivers/thermal/cpu_cooling.c | 28 ++-------------- include/linux/cpu_cooling.h | 53 ++++++++----------------------- 7 files changed, 23 insertions(+), 80 deletions(-) (limited to 'drivers/cpufreq/mediatek-cpufreq.c') diff --git a/Documentation/thermal/cpu-cooling-api.txt b/Documentation/thermal/cpu-cooling-api.txt index ea61e8bf7e2b..7a1c89db0419 100644 --- a/Documentation/thermal/cpu-cooling-api.txt +++ b/Documentation/thermal/cpu-cooling-api.txt @@ -26,24 +26,16 @@ the user. The registration APIs returns the cooling device pointer. clip_cpus: cpumask of cpus where the frequency constraints will happen. 1.1.2 struct thermal_cooling_device *of_cpufreq_cooling_register( - struct device_node *np, const struct cpumask *clip_cpus) + struct cpufreq_policy *policy) This interface function registers the cpufreq cooling device with the name "thermal-cpufreq-%x" linking it with a device tree node, in order to bind it via the thermal DT code. This api can support multiple instances of cpufreq cooling devices. - np: pointer to the cooling device device tree node - clip_cpus: cpumask of cpus where the frequency constraints will happen. - -1.1.3 struct thermal_cooling_device *of_cpufreq_power_cooling_register( - struct cpufreq_policy *policy) - -Similar to cpufreq_cooling_register, this function register a -cpufreq cooling device with power extensions using the device tree -information supplied by the np parameter. + policy: CPUFreq policy. -1.1.4 void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev) +1.1.3 void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev) This interface function unregisters the "thermal-cpufreq-%x" cooling device. diff --git a/drivers/cpufreq/arm_big_little.c b/drivers/cpufreq/arm_big_little.c index 3d5ed4ef3927..c56b57dcfda5 100644 --- a/drivers/cpufreq/arm_big_little.c +++ b/drivers/cpufreq/arm_big_little.c @@ -532,7 +532,7 @@ static void bL_cpufreq_ready(struct cpufreq_policy *policy) if (cur_cluster >= MAX_CLUSTERS) return; - cdev[cur_cluster] = of_cpufreq_power_cooling_register(policy); + cdev[cur_cluster] = of_cpufreq_cooling_register(policy); } static struct cpufreq_driver bL_cpufreq_driver = { diff --git a/drivers/cpufreq/cpufreq-dt.c b/drivers/cpufreq/cpufreq-dt.c index 1e7bec7694ab..de3d104c25d7 100644 --- a/drivers/cpufreq/cpufreq-dt.c +++ b/drivers/cpufreq/cpufreq-dt.c @@ -320,7 +320,7 @@ static void cpufreq_ready(struct cpufreq_policy *policy) { struct private_data *priv = policy->driver_data; - priv->cdev = of_cpufreq_power_cooling_register(policy); + priv->cdev = of_cpufreq_cooling_register(policy); } static struct cpufreq_driver dt_cpufreq_driver = { diff --git a/drivers/cpufreq/mediatek-cpufreq.c b/drivers/cpufreq/mediatek-cpufreq.c index 6ff783e1b18a..f95975b76d98 100644 --- a/drivers/cpufreq/mediatek-cpufreq.c +++ b/drivers/cpufreq/mediatek-cpufreq.c @@ -311,7 +311,7 @@ static void mtk_cpufreq_ready(struct cpufreq_policy *policy) { struct mtk_cpu_dvfs_info *info = policy->driver_data; - info->cdev = of_cpufreq_power_cooling_register(policy); + info->cdev = of_cpufreq_cooling_register(policy); } static int mtk_cpu_dvfs_info_init(struct mtk_cpu_dvfs_info *info, int cpu) diff --git a/drivers/cpufreq/qoriq-cpufreq.c b/drivers/cpufreq/qoriq-cpufreq.c index 3a665c18e14e..0562761a3dec 100644 --- a/drivers/cpufreq/qoriq-cpufreq.c +++ b/drivers/cpufreq/qoriq-cpufreq.c @@ -276,7 +276,7 @@ static void qoriq_cpufreq_ready(struct cpufreq_policy *policy) { struct cpu_data *cpud = policy->driver_data; - cpud->cdev = of_cpufreq_power_cooling_register(policy); + cpud->cdev = of_cpufreq_cooling_register(policy); } static struct cpufreq_driver qoriq_cpufreq_driver = { diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c index 10199f7e1196..3371caf3095c 100644 --- a/drivers/thermal/cpu_cooling.c +++ b/drivers/thermal/cpu_cooling.c @@ -819,7 +819,6 @@ EXPORT_SYMBOL_GPL(cpufreq_cooling_register); /** * of_cpufreq_cooling_register - function to create cpufreq cooling device. - * @np: a valid struct device_node to the cooling device device tree node * @policy: cpufreq policy * * This interface function registers the cpufreq cooling device with the name @@ -827,29 +826,6 @@ EXPORT_SYMBOL_GPL(cpufreq_cooling_register); * cooling devices. Using this API, the cpufreq cooling device will be * linked to the device tree node provided. * - * Return: a valid struct thermal_cooling_device pointer on success, - * on failure, it returns a corresponding ERR_PTR(). - */ -struct thermal_cooling_device * -of_cpufreq_cooling_register(struct device_node *np, - struct cpufreq_policy *policy) -{ - if (!np) - return ERR_PTR(-EINVAL); - - return __cpufreq_cooling_register(np, policy, 0, NULL); -} -EXPORT_SYMBOL_GPL(of_cpufreq_cooling_register); - -/** - * of_cpufreq_power_cooling_register() - create cpufreq cooling device with power extensions - * @policy: CPUFreq policy. - * - * This interface function registers the cpufreq cooling device with - * the name "thermal-cpufreq-%x". This api can support multiple - * instances of cpufreq cooling devices. Using this API, the cpufreq - * cooling device will be linked to the device tree node of the provided - * policy's CPU. * Using this function, the cooling device will implement the power * extensions by using a simple cpu power model. The cpus must have * registered their OPPs using the OPP library. @@ -861,7 +837,7 @@ EXPORT_SYMBOL_GPL(of_cpufreq_cooling_register); * and NULL on failure. */ struct thermal_cooling_device * -of_cpufreq_power_cooling_register(struct cpufreq_policy *policy) +of_cpufreq_cooling_register(struct cpufreq_policy *policy) { struct device_node *np = of_get_cpu_node(policy->cpu, NULL); struct thermal_cooling_device *cdev = NULL; @@ -889,7 +865,7 @@ of_cpufreq_power_cooling_register(struct cpufreq_policy *policy) of_node_put(np); return cdev; } -EXPORT_SYMBOL(of_cpufreq_power_cooling_register); +EXPORT_SYMBOL_GPL(of_cpufreq_cooling_register); /** * cpufreq_cooling_unregister - function to remove cpufreq cooling device. diff --git a/include/linux/cpu_cooling.h b/include/linux/cpu_cooling.h index c35778960a9c..fd0ea8ddca93 100644 --- a/include/linux/cpu_cooling.h +++ b/include/linux/cpu_cooling.h @@ -41,33 +41,6 @@ typedef int (*get_static_t)(cpumask_t *cpumask, int interval, struct thermal_cooling_device * cpufreq_cooling_register(struct cpufreq_policy *policy); -/** - * of_cpufreq_cooling_register - create cpufreq cooling device based on DT. - * @np: a valid struct device_node to the cooling device device tree node. - * @policy: cpufreq policy. - */ -#ifdef CONFIG_THERMAL_OF -struct thermal_cooling_device * -of_cpufreq_cooling_register(struct device_node *np, - struct cpufreq_policy *policy); - -struct thermal_cooling_device * -of_cpufreq_power_cooling_register(struct cpufreq_policy *policy); -#else -static inline struct thermal_cooling_device * -of_cpufreq_cooling_register(struct device_node *np, - struct cpufreq_policy *policy) -{ - return ERR_PTR(-ENOSYS); -} - -static inline struct thermal_cooling_device * -of_cpufreq_power_cooling_register(struct cpufreq_policy *policy) -{ - return NULL; -} -#endif - /** * cpufreq_cooling_unregister - function to remove cpufreq cooling device. * @cdev: thermal cooling device pointer. @@ -81,24 +54,26 @@ cpufreq_cooling_register(struct cpufreq_policy *policy) return ERR_PTR(-ENOSYS); } -static inline struct thermal_cooling_device * -of_cpufreq_cooling_register(struct device_node *np, - struct cpufreq_policy *policy) +static inline +void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev) { - return ERR_PTR(-ENOSYS); + return; } +#endif /* CONFIG_CPU_THERMAL */ +#if defined(CONFIG_THERMAL_OF) && defined(CONFIG_CPU_THERMAL) +/** + * of_cpufreq_cooling_register - create cpufreq cooling device based on DT. + * @policy: cpufreq policy. + */ +struct thermal_cooling_device * +of_cpufreq_cooling_register(struct cpufreq_policy *policy); +#else static inline struct thermal_cooling_device * -of_cpufreq_power_cooling_register(struct cpufreq_policy *policy) +of_cpufreq_cooling_register(struct cpufreq_policy *policy) { return NULL; } - -static inline -void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev) -{ - return; -} -#endif /* CONFIG_CPU_THERMAL */ +#endif /* defined(CONFIG_THERMAL_OF) && defined(CONFIG_CPU_THERMAL) */ #endif /* __CPU_COOLING_H__ */ -- cgit v1.2.3