Age | Commit message (Collapse) | Author | Files | Lines | |
---|---|---|---|---|---|
2019-05-30 | treewide: Replace GPLv2 boilerplate/reference with SPDX - rule 157 | Thomas Gleixner | 1 | -10/+1 | |
Based on 3 normalized pattern(s): this program is free software you can redistribute it and or modify it under the terms of the gnu general public license as published by the free software foundation either version 2 of the license or at your option any later version this program is distributed in the hope that it will be useful but without any warranty without even the implied warranty of merchantability or fitness for a particular purpose see the gnu general public license for more details this program is free software you can redistribute it and or modify it under the terms of the gnu general public license as published by the free software foundation either version 2 of the license or at your option any later version [author] [kishon] [vijay] [abraham] [i] [kishon]@[ti] [com] this program is distributed in the hope that it will be useful but without any warranty without even the implied warranty of merchantability or fitness for a particular purpose see the gnu general public license for more details this program is free software you can redistribute it and or modify it under the terms of the gnu general public license as published by the free software foundation either version 2 of the license or at your option any later version [author] [graeme] [gregory] [gg]@[slimlogic] [co] [uk] [author] [kishon] [vijay] [abraham] [i] [kishon]@[ti] [com] [based] [on] [twl6030]_[usb] [c] [author] [hema] [hk] [hemahk]@[ti] [com] this program is distributed in the hope that it will be useful but without any warranty without even the implied warranty of merchantability or fitness for a particular purpose see the gnu general public license for more details extracted by the scancode license scanner the SPDX license identifier GPL-2.0-or-later has been chosen to replace the boilerplate/reference in 1105 file(s). Signed-off-by: Thomas Gleixner <tglx@linutronix.de> Reviewed-by: Allison Randal <allison@lohutok.net> Reviewed-by: Richard Fontana <rfontana@redhat.com> Reviewed-by: Kate Stewart <kstewart@linuxfoundation.org> Cc: linux-spdx@vger.kernel.org Link: https://lkml.kernel.org/r/20190527070033.202006027@linutronix.de Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org> | |||||
2018-10-25 | thermal: da9062/61: Prevent hardware access during system suspend | Geert Uytterhoeven | 1 | -2/+2 | |
The workqueue used for monitoring the hardware may run while the device is already suspended. Fix this by using the freezable system workqueue instead, cfr. commit 51e20d0e3a60cf46 ("thermal: Prevent polling from happening during system suspend"). Fixes: 608567aac3206ae8 ("thermal: da9062/61: Thermal junction temperature monitoring driver") Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be> Acked-by: Steve Twiss <stwiss.opensource@diasemi.com> Signed-off-by: Eduardo Valentin <edubezval@gmail.com> | |||||
2017-04-07 | thermal: da9062/61: Thermal junction temperature monitoring driver | Steve Twiss | 1 | -0/+315 | |
Add junction temperature monitoring supervisor device driver, compatible with the DA9062 and DA9061 PMICs. A MODULE_DEVICE_TABLE() macro is added. If the PMIC's internal junction temperature rises above T_WARN (125 degC) an interrupt is issued. This T_WARN level is defined as the THERMAL_TRIP_HOT trip-wire inside the device driver. The thermal triggering mechanism is interrupt based and happens when the temperature rises above a given threshold level. The component cannot return an exact temperature, it only has knowledge if the temperature is above or below a given threshold value. A status bit must be polled to detect when the temperature falls below that threshold level again. A kernel work queue is configured to repeatedly poll and detect when the temperature falls below this trip-wire, between 1 and 10 second intervals (defaulting at 3 seconds). This scheme is provided as an example. It would be expected that any final implementation will also include a notify() function and any of these settings could be altered to match the application where appropriate. When over-temperature is reached, the interrupt from the DA9061/2 will be repeatedly triggered. The IRQ is therefore disabled when the first over-temperature event happens and the status bit is polled using a work-queue until it becomes false. This strategy is designed to allow the periodic transmission of uevents (HOT trip point) as the first level of temperature supervision method. It is intended for non-invasive temperature control, where the necessary measures for cooling the system down are left to the host software. Once the temperature falls again, the IRQ is re-enabled so a new critical over-temperature event can be detected. Reviewed-by: Lukasz Luba <lukasz.luba@arm.com> Signed-off-by: Steve Twiss <stwiss.opensource@diasemi.com> Signed-off-by: Eduardo Valentin <edubezval@gmail.com> |