2015-08-10 | clockevents/drivers/meson6: Migrate to new 'set-state' interface | Viresh Kumar | 1 | -23/+27 | |
Migrate meson6 driver to the new 'set-state' interface provided by clockevents core, the earlier 'set-mode' interface is marked obsolete now. This also enables us to implement callbacks for new states of clockevent devices, for example: ONESHOT_STOPPED. Cc: Carlo Caione <carlo@caione.org> Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Acked-by: Carlo Caione <carlo@caione.org> | |||||
2014-09-29 | ARM: meson6: clocksource: Add Meson6 timer support | Carlo Caione | 1 | -0/+167 | |
Meson6 SoCs are equipped with 5 32-bit timers, called TIMER_A, TIMER_B, TIMER_C, TIMER_D and TIMER_E. The driver is providing clocksource support for the 32-bit counter using TIMER_E. Clockevents are also supported using TIMER_A. Acked-by: Arnd Bergmann <arnd@arndb.de> Signed-off-by: Carlo Caione <carlo@caione.org> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Reviewed-by: Matthias Brugger <matthias.bgg@gmail.com> |