Age | Commit message (Collapse) | Author | Files | Lines |
|
Add a pointer to the system call table to the thread_info structure.
The TIF_31BIT bit is set or cleared by SET_PERSONALITY exactly once
for the lifetime of a process. With the pointer to the correct system
call table in thread_info the system call code in entry64.S path can
drop the check for TIF_31BIT which saves a couple of instructions.
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
|
|
Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
|
|
Move the program interruption code and the translation exception identifier
to the pt_regs structure as 'int_code' and 'int_parm_long' and make the
first level interrupt handler in entry[64].S store the two values. That
makes it possible to drop 'prot_addr' and 'trap_no' from the thread_struct
and to reduce the number of arguments to a lot of functions. Finally
un-inline do_trap. Overall this saves 5812 bytes in the .text section of
the 64 bit kernel.
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
|
|
Add an explicit TIF_SYSCALL bit that indicates if a task is inside
a system call. The svc_code in the pt_regs structure is now only
valid if TIF_SYSCALL is set. With this definition TIF_RESTART_SVC
can be replaced with TIF_SYSCALL. Overall do_signal is a bit more
readable and it saves a few lines of code.
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
|
|
For a ERESTARTNOHAND/ERESTARTSYS/ERESTARTNOINTR restarting system call
do_signal will prepare the restart of the system call with a rewind of
the PSW before calling get_signal_to_deliver (where the debugger might
take control). For A ERESTART_RESTARTBLOCK restarting system call
do_signal will set -EINTR as return code.
There are two issues with this approach:
1) strace never sees ERESTARTNOHAND, ERESTARTSYS, ERESTARTNOINTR or
ERESTART_RESTARTBLOCK as the rewinding already took place or the
return code has been changed to -EINTR
2) if get_signal_to_deliver does not return with a signal to deliver
the restart via the repeat of the svc instruction is left in place.
This opens a race if another signal is made pending before the
system call instruction can be reexecuted. The original system call
will be restarted even if the second signal would have ended the
system call with -EINTR.
These two issues can be solved by dropping the early rewind of the
system call before get_signal_to_deliver has been called and by using
the TIF_RESTART_SVC magic to do the restart if no signal has to be
delivered. The only situation where the system call restart via the
repeat of the svc instruction is appropriate is when a SA_RESTART
signal is delivered to user space.
Unfortunately this breaks inferior calls by the debugger again. The
system call number and the length of the system call instruction is
lost over the inferior call and user space will see ERESTARTNOHAND/
ERESTARTSYS/ERESTARTNOINTR/ERESTART_RESTARTBLOCK. To correct this a
new ptrace interface is added to save/restore the system call number
and system call instruction length.
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
|
|
Do the setup of the stack overflow argument for the sixth system
call parameter right before the branch to the system call function.
That simplifies the system call parameter access code.
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
|
|
Most implementations of arch_syscall_addr() are the same, so create a
default version in common code and move the one piece that differs (the
syscall table) to asm/syscall.h. New arch ports don't have to waste
time copying & pasting this simple function.
The s390/sparc versions need to be different, so document why.
Signed-off-by: Mike Frysinger <vapier@gentoo.org>
Acked-by: David S. Miller <davem@davemloft.net>
Acked-by: Paul Mundt <lethal@linux-sh.org>
Acked-by: Heiko Carstens <heiko.carstens@de.ibm.com>
Cc: Steven Rostedt <rostedt@goodmis.org>
LKML-Reference: <1264498803-17278-1-git-send-email-vapier@gentoo.org>
Signed-off-by: Frederic Weisbecker <fweisbec@gmail.com>
|
|
System call tracer support for s390.
Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
|
|
syscall_get_nr() currently returns a valid result only if the call
chain of the traced process includes do_syscall_trace_enter(). But
collect_syscall() can be called for any sleeping task, the result of
syscall_get_nr() in general is completely bogus.
To make syscall_get_nr() work for any sleeping task the traps field
in pt_regs is replace with svcnr - the system call number the process
is executing. If svcnr == 0 the process is not on a system call path.
The syscall_get_arguments and syscall_set_arguments use regs->gprs[2]
for the first system call parameter. This is incorrect since gprs[2]
may have been overwritten with the system call number if the call
chain includes do_syscall_trace_enter. Use regs->orig_gprs2 instead.
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
|
|
* System call parameter and result access functions
* Add tracehook calls
* Split syscall_trace into two functions do_syscall_trace_enter and
do_syscall_trace_exit
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
|