summaryrefslogtreecommitdiff
path: root/drivers/thermal/cpu_cooling.c
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/thermal/cpu_cooling.c')
-rw-r--r--drivers/thermal/cpu_cooling.c56
1 files changed, 50 insertions, 6 deletions
diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
index bb486b4ca48e..4246262c4bd2 100644
--- a/drivers/thermal/cpu_cooling.c
+++ b/drivers/thermal/cpu_cooling.c
@@ -424,18 +424,21 @@ static struct notifier_block thermal_cpufreq_notifier_block = {
};
/**
- * cpufreq_cooling_register - function to create cpufreq cooling device.
+ * __cpufreq_cooling_register - helper function to create cpufreq cooling device
+ * @np: a valid struct device_node to the cooling device device tree node
* @clip_cpus: cpumask of cpus where the frequency constraints will happen.
*
* This interface function registers the cpufreq cooling device with the name
* "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
- * cooling devices.
+ * cooling devices. It also gives the opportunity to link the cooling device
+ * with a device tree node, in order to bind it via the thermal DT code.
*
* Return: a valid struct thermal_cooling_device pointer on success,
* on failure, it returns a corresponding ERR_PTR().
*/
-struct thermal_cooling_device *
-cpufreq_cooling_register(const struct cpumask *clip_cpus)
+static struct thermal_cooling_device *
+__cpufreq_cooling_register(struct device_node *np,
+ const struct cpumask *clip_cpus)
{
struct thermal_cooling_device *cool_dev;
struct cpufreq_cooling_device *cpufreq_dev = NULL;
@@ -474,8 +477,8 @@ cpufreq_cooling_register(const struct cpumask *clip_cpus)
snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",
cpufreq_dev->id);
- cool_dev = thermal_cooling_device_register(dev_name, cpufreq_dev,
- &cpufreq_cooling_ops);
+ cool_dev = thermal_of_cooling_device_register(np, dev_name, cpufreq_dev,
+ &cpufreq_cooling_ops);
if (IS_ERR(cool_dev)) {
release_idr(&cpufreq_idr, cpufreq_dev->id);
kfree(cpufreq_dev);
@@ -495,9 +498,50 @@ cpufreq_cooling_register(const struct cpumask *clip_cpus)
return cool_dev;
}
+
+/**
+ * cpufreq_cooling_register - function to create cpufreq cooling device.
+ * @clip_cpus: cpumask of cpus where the frequency constraints will happen.
+ *
+ * This interface function registers the cpufreq cooling device with the name
+ * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
+ * cooling devices.
+ *
+ * Return: a valid struct thermal_cooling_device pointer on success,
+ * on failure, it returns a corresponding ERR_PTR().
+ */
+struct thermal_cooling_device *
+cpufreq_cooling_register(const struct cpumask *clip_cpus)
+{
+ return __cpufreq_cooling_register(NULL, clip_cpus);
+}
EXPORT_SYMBOL_GPL(cpufreq_cooling_register);
/**
+ * of_cpufreq_cooling_register - function to create cpufreq cooling device.
+ * @np: a valid struct device_node to the cooling device device tree node
+ * @clip_cpus: cpumask of cpus where the frequency constraints will happen.
+ *
+ * This interface function registers the cpufreq cooling device with the name
+ * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
+ * cooling devices. Using this API, the cpufreq cooling device will be
+ * linked to the device tree node provided.
+ *
+ * Return: a valid struct thermal_cooling_device pointer on success,
+ * on failure, it returns a corresponding ERR_PTR().
+ */
+struct thermal_cooling_device *
+of_cpufreq_cooling_register(struct device_node *np,
+ const struct cpumask *clip_cpus)
+{
+ if (!np)
+ return ERR_PTR(-EINVAL);
+
+ return __cpufreq_cooling_register(np, clip_cpus);
+}
+EXPORT_SYMBOL_GPL(of_cpufreq_cooling_register);
+
+/**
* cpufreq_cooling_unregister - function to remove cpufreq cooling device.
* @cdev: thermal cooling device pointer.
*