diff options
Diffstat (limited to 'Documentation/hwmon/sht3x')
-rw-r--r-- | Documentation/hwmon/sht3x | 76 |
1 files changed, 0 insertions, 76 deletions
diff --git a/Documentation/hwmon/sht3x b/Documentation/hwmon/sht3x deleted file mode 100644 index d9daa6ab1e8e..000000000000 --- a/Documentation/hwmon/sht3x +++ /dev/null @@ -1,76 +0,0 @@ -Kernel driver sht3x -=================== - -Supported chips: - * Sensirion SHT3x-DIS - Prefix: 'sht3x' - Addresses scanned: none - Datasheet: https://www.sensirion.com/file/datasheet_sht3x_digital - -Author: - David Frey <david.frey@sensirion.com> - Pascal Sachs <pascal.sachs@sensirion.com> - -Description ------------ - -This driver implements support for the Sensirion SHT3x-DIS chip, a humidity -and temperature sensor. Temperature is measured in degrees celsius, relative -humidity is expressed as a percentage. In the sysfs interface, all values are -scaled by 1000, i.e. the value for 31.5 degrees celsius is 31500. - -The device communicates with the I2C protocol. Sensors can have the I2C -addresses 0x44 or 0x45, depending on the wiring. See -Documentation/i2c/instantiating-devices for methods to instantiate the device. - -There are two options configurable by means of sht3x_platform_data: -1. blocking (pull the I2C clock line down while performing the measurement) or - non-blocking mode. Blocking mode will guarantee the fastest result but - the I2C bus will be busy during that time. By default, non-blocking mode - is used. Make sure clock-stretching works properly on your device if you - want to use blocking mode. -2. high or low accuracy. High accuracy is used by default and using it is - strongly recommended. - -The sht3x sensor supports a single shot mode as well as 5 periodic measure -modes, which can be controlled with the update_interval sysfs interface. -The allowed update_interval in milliseconds are as follows: - * 0 single shot mode - * 2000 0.5 Hz periodic measurement - * 1000 1 Hz periodic measurement - * 500 2 Hz periodic measurement - * 250 4 Hz periodic measurement - * 100 10 Hz periodic measurement - -In the periodic measure mode, the sensor automatically triggers a measurement -with the configured update interval on the chip. When a temperature or humidity -reading exceeds the configured limits, the alert attribute is set to 1 and -the alert pin on the sensor is set to high. -When the temperature and humidity readings move back between the hysteresis -values, the alert bit is set to 0 and the alert pin on the sensor is set to -low. - -sysfs-Interface ---------------- - -temp1_input: temperature input -humidity1_input: humidity input -temp1_max: temperature max value -temp1_max_hyst: temperature hysteresis value for max limit -humidity1_max: humidity max value -humidity1_max_hyst: humidity hysteresis value for max limit -temp1_min: temperature min value -temp1_min_hyst: temperature hysteresis value for min limit -humidity1_min: humidity min value -humidity1_min_hyst: humidity hysteresis value for min limit -temp1_alarm: alarm flag is set to 1 if the temperature is outside the - configured limits. Alarm only works in periodic measure mode -humidity1_alarm: alarm flag is set to 1 if the humidity is outside the - configured limits. Alarm only works in periodic measure mode -heater_enable: heater enable, heating element removes excess humidity from - sensor - 0: turned off - 1: turned on -update_interval: update interval, 0 for single shot, interval in msec - for periodic measurement. If the interval is not supported - by the sensor, the next faster interval is chosen |